Start-up procedure


Q  -  When is it recommended to start a pump with the discharge control valve
closed, and when is it with the discharge control valve opened?



A  -  A pump should be started in a manner that its required starting torque is at
the lowest possible.


Since torque is directly proportional to the brake horsepower (BHP), then a pump
should be started with the discharge control valve either closed, or opened,
depending on whether the lowest required BHP as shown in its performance
curve, is near the shut-off capacity (start the pump with the valve closed), or near
the end-of-curve (start with the valve opened.)


Generally, radial and mixed-flow type pumps have their
lowest required BHP near
the shut-off capacity with the BHP
increasing towards the higher flow rates, and
should therefore be started with the discharge valve closed.


In contrast, axial flow type pumps generally have their
highest required BHP near
the shut-off capacity, with the BHP
decreasing towards the higher flow rates, and
should therefore be started with the discharge valve opened.


When starting a unit with the discharge valve closed, the valve should be opened
gradually as soon as the driver reaches its full speed. Operating it over a longer
period of time with its discharge valve closed can result in unwanted, sometimes
destructive, temperature rise in the casing.


R0609-STPR
File: start-up

"Make it simple"
CENTRIFUGAL-PUMP.ORG
TECHNICAL

Concepts

Parts

Auxiliaries

Glossary

Engineering data

Library

Bulletin board




Go to our Sitemap
for list of articles



By accessing this site
you agree to our
Terms of Use and
Legal Disclaimer



Copyright notice
Privacy policy
Custom Search